Coming soon: the guides go on sale shortly. The free sample is open now.

Practice tests · NFPA 1001 / 1010

Fire Fighter Level I

5,562 exam-style questions across 21 chapters, each with an explanation of why the right answer is right.

$44.9512 months access

Also in these bundles:

Level I Complete$69.95

Everything$119.95

What a test looks like

Practice

25, 50 or 100 questions. See the right answer and the reason straight after each one.

Exam

25, 50 or 100 questions with no feedback until you submit. Then your score, your weakest areas and every miss explained.

Chapter practice

Pick the chapters you want to work on and drill just those.

Every test is a fresh draw from the whole guide, with the answer options reshuffled. Questions you have seen recently are held back until the pool runs low.

What the exam covers

The written Fire Fighter Level I exam tests the knowledge behind the Fire Fighter I job performance requirements: the fire service and fire fighter safety, protective equipment and SCBA, communications, fire behaviour, building construction, extinguishers, tools, ropes and knots, forcible entry, ladders, search and rescue, ventilation, water supply, hose and nozzles, fire suppression, survival, salvage and overhaul, rehabilitation, and wildland and ground cover fires.

Questions are tagged to both NFPA 1001 (2019 edition), Chapter 4, and NFPA 1010 (2024 edition), Chapter 6, the Fire Fighter I requirements, so the guide fits either standard.

In Manitoba this guide covers the theory for MESC course 998910, Fire Fighting Level I. MESC requires Hazardous Materials Operations before it issues Level I seals; the Level I Complete bundle pairs the two guides.

Firehouse Fundamentals is a study aid for the written exam. It does not certify anyone; your training program and certifying body set and mark the exam.

Try 3 questions

From the free sample: the kind of question every Fire Fighter Level I test is made of, with the explanation you get after each answer.

  1. Fire Behaviour

    Windows are darkened but little smoke is moving around the closed doors and windows. What does that suggest?

    Show the answer

    A ventilation-limited fire in decay, with backdraft potential

    Darkened windows with little smoke movement point to a hot fire that has gone ventilation-limited and entered decay, which is a sign of great danger. As soon as that fire gets a fresh supply of oxygen through a door, window or other opening, it will likely produce rapid fire growth and possibly a backdraft.

  2. Fire Fighter Survival

    A fire fighter is disoriented, low on air and separated from their crew. What is the correct immediate action?

    Show the answer

    Transmit a mayday at once, then activate the PASS device and attempt self-rescue

    Call the mayday as soon as you think you are in trouble, giving who you are, what is wrong and where you are, then manually activate the PASS device and attempt self-rescue. Waiting until the air is almost gone is the delay that has cost fire fighters their lives.

  3. Ventilation

    A vent crew is ready but the attack line is not yet charged. What should happen?

    Show the answer

    Delay the vent until the line is charged

    A charged line takes time to get into place, so the opening should sometimes wait until the line is ready and the crew can apply water from a close, safe position. Venting first simply feeds the fire.

Take all ten free questions

Chapters in this guide

  • The Fire Service
  • Fire Fighter Health and Safety
  • Personal Protective Equipment
  • Fire Service Communications
  • Fire Behaviour
  • Building Construction
  • Portable Fire Extinguishers
  • Fire Fighter Tools and Equipment
  • Ropes and Knots
  • Forcible Entry
  • Ladders
  • Search and Rescue
  • Ventilation
  • Water Supply Systems
  • Fire Hose, Appliances, and Nozzles
  • Supply Line and Attack Line Evolutions
  • Fire Suppression
  • Fire Fighter Survival
  • Salvage and Overhaul
  • Fire Fighter Rehabilitation
  • Wildland and Ground Cover Fires